- | Exxactcorp: For the GPU discussion, 2 to 4 GPUs per node is fine. T4 GPU is 100% fine , and the passive heatsink is better not worse. The system needs to be one that supports passive Tesla cards and the chassis fans would simply ramp to cool the card properly, as in any passive tesla situation. | + | **Exxactcorp**: For the GPU discussion, 2 to 4 GPUs per node is fine. T4 GPU is 100% fine , and the passive heatsink is better not worse. The system needs to be one that supports passive Tesla cards and the chassis fans would simply ramp to cool the card properly, as in any passive tesla situation. |
+ | |||
+ | **Microway**: | ||
+ | |||
+ | **conRes**: In regards to the question around active vs. passive cooling on GPUs, the T4, V100, and other passively cooled GPUs are intended for 100% utilization and actually can offer better cooling and higher density in a system than active GPU models. | ||
- | Microway: For this mix of workloads two to four GPUs per node is a good balance. Passive GPUs are *better* for HPC usage. All Tesla GPUs for the last 5? years have been passive. I'd be happy to help allay any concerns you may have there. The short version is that the GPU and the server platform communicate as to the GPUs temperature. The server adjusts fan speeds appropriately and is able to move far more air than a built-in fan would ever be able to. | ||