This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
cluster:89 [2010/08/14 00:51] hmeij |
cluster:89 [2010/08/17 17:52] hmeij |
||
---|---|---|---|
Line 14: | Line 14: | ||
* Delivery on standard raised dock, no ways to lift rack out of truck if not docked | * Delivery on standard raised dock, no ways to lift rack out of truck if not docked | ||
* Freight Elevator and pallet jack available | * Freight Elevator and pallet jack available | ||
+ | |||
+ | ===== Network ===== | ||
+ | |||
+ | Basically ... | ||
+ | |||
+ | * x.y.z.255 is broadcast | ||
+ | * x.y.z.254 is head or log in node | ||
+ | * x.y.z.0 is gateway | ||
+ | * x.y.z.< | ||
+ | * x.y.z.25( up to 253) is for all compute nodes | ||
+ | |||
+ | We are planning to ingest our Dell cluster (37 nodes) and our Blue Sky Studios cluster (130 nodes) into this setup, hence the approach. | ||
+ | |||
+ | Netmask is, finally, 255.255.0.0 (excluding public 129.133 subnet). | ||
===== DM380G7 ===== | ===== DM380G7 ===== | ||
- | [[http:// | + | [[http:// |
* Dual power (one to UPS, one to utility, do later) | * Dual power (one to UPS, one to utility, do later) | ||
- | * hostname [[http:// | + | * hostname [[http:// |
* eth0, provision, 192.168.102.254/ | * eth0, provision, 192.168.102.254/ | ||
* eth1, data/ | * eth1, data/ | ||
* eth2, public, 129.133.1.226/ | * eth2, public, 129.133.1.226/ | ||
- | * eth3, ipmi, 10.10.103.254/ | + | * eth3, ipmi, 192.168.103.254/ |
- | * ib0, ipoib, 10.10.104.254/ | + | * ib0, ipoib, 10.10.103.254/ |
- | * ib1, ipoib, 10.10.105.254/ | + | * ib1, ipoib, 10.10.104.254/ |
* Raid 1 mirrored disks (2x250gb) | * Raid 1 mirrored disks (2x250gb) | ||
Line 34: | Line 48: | ||
* logical volume LOCALSCRATCH: | * logical volume LOCALSCRATCH: | ||
* logical volumes ROOT/ | * logical volumes ROOT/ | ||
+ | |||
+ | * IPoIB configuration | ||
+ | * SIM configuration | ||
+ | * CMU configuration | ||
+ | * SGE configuration | ||
===== StorageWorks MSA60 ===== | ===== StorageWorks MSA60 ===== | ||
- | [[http:// | + | [[http:// |
- | * Dual power (one to UPS, one to utility) | + | |
+ | * Dual power (one to UPS, one to utility, do later) | ||
* Three volumes to start with: | * Three volumes to start with: | ||
- | * home (raid 6, design a backup path, do later) | + | * home (raid 6, design a backup path, do later), 10 tb |
- | * apps (raid 6, design a backup path, do later) | + | * apps (raid 6, design a backup path, do later), 1tb |
- | * sanscratch (raid 1, no backup) | + | * sanscratch (raid 1, no backup), 5 tb |
+ | |||
+ | * SIM | ||
- | * Systems Insight Manager (SIM) | ||
- | * install, configure, monitor, actions | ||
===== SL2x170z G6 ===== | ===== SL2x170z G6 ===== | ||
- | [[http:// | + | [[http:// |
* node names hp000, increment by 1 | * node names hp000, increment by 1 | ||
- | * eth0, provision, 192.168.102.10(increment by 1)/ | + | * eth0, provision, 192.168.102.25(increment by 1)/ |
- | * eth1, data/ | + | * eth1, data/ |
- | * eth2, ipmi, 10.10.103.10(increment by 1)/ | + | * eth2, ipmi, 192.168.103.25(increment by 1)/ |
- | * ib0, ipoib, 10.10.104.10(increment by 1)/ | + | * ib0, ipoib, 10.10.103.25(increment by 1)/ |
- | * ib1, ipoib, 10.10.105.10(increment by 1)/ | + | * ib1, ipoib, 10.10.104.25(increment by 1)/ |
* /home mount point for home directory volume ~ 10tb | * /home mount point for home directory volume ~ 10tb | ||
Line 63: | Line 83: | ||
* logical volumes ROOT/ | * logical volumes ROOT/ | ||
+ | * SIM | ||
===== Misc ===== | ===== Misc ===== | ||
Line 70: | Line 91: | ||
* monitor | * monitor | ||
- | * Cluster Management Utility (CMU) | + | |
+ | * Do we need a windows box (virtual) to run the Central Management Server on? | ||
+ | * SIM + Cluster Monitor (MSCS)? | ||
+ | * install, configure | ||
+ | * requires an oracle install? no, hpsmdb is installed with automatic installation (postgresql) | ||
+ | * linux deployment utilities, and management agents installation | ||
+ | * configure managed systems, automatic discovery | ||
+ | * configure automatic event handling | ||
+ | |||
+ | | ||
* install, configure, monitor | * install, configure, monitor | ||
* golden image capture, deploy (there will initially only be one image) | * golden image capture, deploy (there will initially only be one image) | ||
Line 77: | Line 107: | ||
* install, configure | * install, configure | ||
* there will only be one queue (hp12) | * there will only be one queue (hp12) | ||
+ | |||
+ | ===== Other ===== | ||
* KVM utility | * KVM utility | ||
* functionality | * functionality | ||
+ | |||
+ | * Placement | ||
+ | * where in data center (do later), based on environmental works | ||
\\ | \\ | ||
**[[cluster: | **[[cluster: |