cluster:89 [2010/08/18 19:23]
hmeij
cluster:89 [2010/08/18 21:39]
hmeij
Line 102: Line 102:
     * monitor     * monitor
  
-  * Systems Insight Manager (SIM) [[http://h18013.www1.hp.com/products/servers/management/hpsim/index.html?jumpid=go/hpsim|HP Link]] (Linux Install and Configure Guide, and User Guide)+  * Systems Insight Manager (SIM)  
 +  * [[http://h18013.www1.hp.com/products/servers/management/hpsim/index.html?jumpid=go/hpsim|HP Link]] (Linux Install and Configure Guide, and User Guide)
     * Do we need a windows box (virtual) to run the Central Management Server on?     * Do we need a windows box (virtual) to run the Central Management Server on?
     * SIM + Cluster Monitor (MSCS)?     * SIM + Cluster Monitor (MSCS)?
Line 111: Line 112:
     * configure automatic event handling     * configure automatic event handling
  
-  * Cluster Management Utility (CMU)[[http://h20338.www2.hp.com/HPC/cache/412128-0-0-0-121.html|HP Link]] (Getting Started - Hardware Preparation, Setup and Install -- Installation Guide v4.2, Users Guides) +  * Cluster Management Utility (CMU up to 4,096 nodes) 
-  * iLo/IPMI+  * [[http://h20338.www2.hp.com/HPC/cache/412128-0-0-0-121.html|HP Link]] (Getting Started - Hardware Preparation, Setup and Install -- Installation Guide v4.2, Users Guides)
     * HP iLo probably removes the need for IPMI, consult [[http://en.wikipedia.org/wiki/HP_Integrated_Lights-Out|External Link]], do the blades have a management card?     * HP iLo probably removes the need for IPMI, consult [[http://en.wikipedia.org/wiki/HP_Integrated_Lights-Out|External Link]], do the blades have a management card?
     * well maybe not, IPMI ([[http://en.wikipedia.org/wiki/Ipmi|External Link]]) can be scripted to power on/off, not sure about iLo (all web based)      * well maybe not, IPMI ([[http://en.wikipedia.org/wiki/Ipmi|External Link]]) can be scripted to power on/off, not sure about iLo (all web based) 
Line 121: Line 122:
     * install X and CMU GUI client node     * install X and CMU GUI client node
     * start CMU, start client, scan for nodes, build golden image     * start CMU, start client, scan for nodes, build golden image
 +    * install monitoring client when building golden image node via CMU GUI
     * clone nodes, deploy management agent on nodes     * clone nodes, deploy management agent on nodes
-    * install monitoring+    * not sure we can implement CMU HA
  
   * Sun Grid Engine (SGE)   * Sun Grid Engine (SGE)
Line 140: Line 142:
 All do later. After HP cluster is up. All do later. After HP cluster is up.
  
-  * Backups.  Use trickery with linux and rsync to provide snapshots? [[http://forum.synology.com/enu/viewtopic.php?f=9&t=11471|External Link]] and another [[http://www.mikerubel.org/computers/rsync_snapshots/|External Link]]+  * Backups.  /snapshot volume 
 +  * Use trickery with linux and rsync to provide snapshots? [[http://forum.synology.com/enu/viewtopic.php?f=9&t=11471|External Link]] and another [[http://www.mikerubel.org/computers/rsync_snapshots/|External Link]]
     * Exclude very large files?     * Exclude very large files?
-    * petaltail:/root/snapshot.sh for example+    * petaltail:/root/snapshot.sh or rotate_backups.sh as examples
     * or better [[http://www.rsnapshot.org/|http://www.rsnapshot.org/]]     * or better [[http://www.rsnapshot.org/|http://www.rsnapshot.org/]]
  
cluster/89.txt · Last modified: 2010/11/22 19:05 by hmeij