This is an old revision of the document!
Back
HP HPC
Notes for the cluster design conference with HP.
“do later” means we tackle after the HP on site visit.
S & H
Shipping Address: 5th floor data center
No 13'6“ truck, 12'6” is ok or box truck
Delivery on standard raised dock, no ways to lift rack out of truck if not docked
Freight Elevator and pallet jack available
Head Node
hostname greentail
eth0, provision, 192.168.102.254/255.255.0.0 (greentail-eth0, should go to better switch ProCurve 2910)
eth1, data/private, 10.10.102.254/255.255.0.0 (greentail-eth1, should go to ProCurve 2610)
eth2, public, 129.133.1.226/255.255.255.0 (greentail.wesleyan.edu)
eth3, ipmi, 10.10.103.254/255.255.0.0, (greentail-ipmi, do later)
ib0, ipoib, 10.10.104.254/255.255.0.0 (greentail-ib0)
ib1, ipoib, 10.10.105.254/255.255.0.0 (greentail-ib1, configure, might not have cables!, split traffic across ports?)
Raid 1 mirrored disks (2x250gb)
/home mount point for home directory volume ~ 10tb
/home/apps mount point for software volume ~ 1tb (contains /home/apps/src)
/home/sanscratch mount point for sanscratch volume ~ 5 tb
logical volume LOCALSCRATCH: mount at /localscratch ~ 100 gb (should match nodes at 160 gb, leave rest for
OS)
logical volumes ROOT/VAR/BOOT/TMP: defaults
Disk Array
Compute Nodes
Misc